Information technology'south common cold outside. You are sitting at home covered in blankets, enjoying a good picture later a long day of hard work. Then a drop of water leaks from your roof onto your head and your peace is ruined. Such can be the case amid winter if proper measures for water ice dams aren't taken.

To forestall further impairment to your rooftop and to secure comfy living space, a roof heating cable will protect y'all from leaking waters. And to make sure it is properly fix upwards, nosotros accept bought you a guide on roof heating cables: how to use.

By following our guidelines on how to install and properly maintain Roof heating cables, you will exist assured a comfy winter.

Rooring PPC Marketing

Roof Heating Cables: How to use

The electric estrus cable gets installed on the superlative of your house roof. We lay it in a zigzag pattern and put it in the gutter into the downspout.

This gives the waters that are coming downwardly from freezing a path to go into the gutter and then into the downspout. Therefore it prevents h2o from getting into your house.

Roof Heating Cables

Advantages Of Roof Heating Cables

By melting ice, information technology lowers the additional weight your roof has to bear. Thus heating cable protects your roof and gutter from damages.

When installed properly, information technology tin can be a quick solution to the ice damps. It is also much less costly than other ways of combating ice damps.

Disadvantages Of Roof Heating Cables

If non installed properly, information technology tin atomic number 82 to a structure fire. In fact, roof heating cables are responsible for effectually 2000 fires a year in the USA alone.

Also, at that place are limits to how much roof heating cables can cover the roof. It just melts the snow that is around it, basically the edge of the roof.

The center, in nigh cases, remains in snow. Furthermore, by the end of winter, in the summer and spring, it does not expect at all pleasing to the eyes.

Rooring PPC Marketing

Necessary Tools To Install A Roof Heating Cablevision

It volition be easier to install if all the necessary tools are gathered before starting the process. The required tools are every bit follows:

  • A hammer
  • Tape measure
  • Ability Screwdriver
  • Heat and Wet Sensors
  • Screws
  • Estrus cable roof clips
  • Waterproof wire
  • Weatherproof box
  • Receptacle

Safety Equipment

Your safety is our priority. So, gather the required safety equipment and vesture them. Necessary rubber equipment are;

  • A sturdy extension ladder
  • Roof brackets
  • A safety harness
  • Lanyard
  • Rope-grab
  • Roof anchor
  • Hand gloves
  • Hearing protection
Roof Heating Cables: How To Use

Installation

You have to follow some steps to install roof heating cables. The step-past-stride guideline is explained beneath.

Step ane

Place clips to the shingles of your roof. These should exist secured in a zigzag germination. The clips should be right in a higher place the gutter. Then place the next ane about 60 degrees to its left or correct.

Pace two

Lay out and adhere the heating cable from ane prune to the side by side. Attaching of cables should also be washed in the zigzag germination.

Rooring PPC Marketing

Step iii

After the entire roof is secured with cables, take hold of the finish of the cables, fold it into a loop. Then apply a prune to hold them together so that you can feed it into the downspout.

Step 4

Mount the sensor with the help of a screwdriver at a corner of your rooftop just below the gutter

Pace 5

Lay the wet lead along the edge of the roof. Use clips to secure them so that they stay along the edge.

Pace half dozen

Now that the laying of cables is consummate, it'south fourth dimension to requite ability upward to the cables.

Pace 7

Sleeve the waterproof wire into your pipage. Install a weatherproof box at the end of it.

Step viii

Install the receptacle inside the box. The cover volition protect everything from water

Step 9

Adhere the outlet to the side of the house to a hole through the piping into the basement where you tin can feed the wire into the panel.

Pace 10

Bang-up piece of work. Installation of estrus cable is complete.

Delight do not skip any of the steps every bit precise installation of cables is required to prevent whatsoever accidents.

Roof Heating Cables: Maintenance

Every bit the sensor of the heating cable is completely automatic, in that location isn't much maintenance to be washed. The sensor will automatically turn on at the correct temperature and moisture which is below 38 degrees Fahrenheit.

It also needs to have moisture on the sensing lead cables. Then, when it's actually cold only it isn't snowing, the cablevision will not exist turned on.

Make sure that the cables are non overheating. Cheque regularly if there is any damage to the cables as it tin lead to a fire.

Verdict

I hope you've a articulate concept now on roof heating cable use. The guideline on roof heating cables: how to use was surely helpful enough for you lot.

It is a matter of great importance that the cables are gear up and maintained properly so that no accidents tin can occur.

And so, follow the step-by-step guideline and live dry out and comfortable inside your warm abode.